Skip to main content

Storage Energy

The Storage Energy results page provides an overview of the storage energy results for the selected system.

Review the tables for a detailed explanation of each variable.

Project Metrics

VariableDescription
Notice to ProceedInput specified in the project Setup
Expected Commercial Operation DateInput specified in project Setup
Nameplate Capacity and PowerNameplate Capacity and Power represent the storage total capacity and power at the COD date.
Capital expensesCapital expenses: sum of capital expenses for storage and the storage dedicated converter in year 0. Capital expenses do not include augmentation costs.
Augmentation limitAugmentation limit is the limit up to which the battery may degrade before being augmented.
LCOSThe per-unit cost of storing electricity over the system’s lifetime. It considers the present value of all costs associated with the energy storage system divided by the total energy stored over its operational lifetime.

Annual Storage Energy

VariableDescription
Minimum and maximum usable energy capacityMinimum and maximum usable energy capacity show the lowest and highest capacity of the storage during that year. The data shows the battery degradation over the course of the year and when the system is augmented.
Storage energy input and outputStorage energy input and output show the annual energy supplied and discharged from the storage system. Round trip efficiency losses are evident in the storage output values.
Cycle costCycle cost is the storage augmentation costs that the model attributes to the specific year divided by the year’s energy throughput times the estimated lifetime.
State of Charge PercentileState of Charge Percentile is the count of timesteps at or above the listed percent divided by total timesteps.
AugmentationAugmentation is the additional capacity installed and is equal to the augmentation degradation limit times the total installed capacity at COD.
Operating expensesOperating expenses are the sum of operating costs related to storage, including the storage dedicated converter operating costs, but excluding replacement or augmentation costs
Equivalent cyclesEquivalent cycles is the annual throughput divided by the storage nameplate capacity